On ship data traffic
Contents
Project Description
NMEA 0183, NMEA 2000 and CAN bus data collected on board of the University of Rostock research vessel Limanda from 2023/06/06 to 2023/10/04.
Contact contributors
Datasets
KNX
ID | File | Reference_ID | Author E-Mail | Notes |
---|---|---|---|---|
1 | https://opsci.informatik.uni-rostock.de/repos/datasets/fieldbus-traffic/knx/attack_free_referencedataset_with_seconds_csv.zip | 1 | Simeon Wiedenmann | A log of normal KNX traffic without any attacks in csv / json format
Zip compressed CSV-file 14,3 MB (uncompressed 302,5 MB) CC BY-SA 4.0 (CSV: Line Separator = LF, Enclosing Strings in = ", Field Separator = ; ) Zip compressed JSON-file 20,8 MB (uncompressed 817,7 MB) CC BY-SA 4.0 Due to too low timestamp resolution in our log-mechanisms the time stamps are only accurate to the second, which is unfortunate. However the temporal order of the telegrams still can be determined by the correctly set sequence_number. For telegrams with identical timestamps, those with lower sequence_number happened earlier. |
2 | https://opsci.informatik.uni-rostock.de/repos/datasets/fieldbus-traffic/knx/attacks_with_seconds_csv.zip | 1 | Simeon Wiedenmann | A log of KNX traffic with artificially introduced attack telegrams deduced from ID = 1 following this documentation and creation script. Introduced attacks are documented at the bottom of that file and include manipulated hop_count values, new source_addresses, time shifted telegrams, replay attacks, negation attacks and the deletion of telegrams.
Due to too low timestamp resolution in our log-mechanisms the time stamps are only accurate to the second, which is unfortunate. However the temporal order of the telegrams still can be determined by the correctly set sequence_number. For telegrams with identical timestamps, those with lower sequence_number happened earlier. |
3 | https://opsci.informatik.uni-rostock.de/repos/datasets/fieldbus-traffic/knx/replay_telegrams.zip
https://opsci.informatik.uni-rostock.de/repos/datasets/fieldbus-traffic/knx/negation_telegrams.zip |
2 and 1 | Simeon Wiedenmann | These zip files contain csv and json versions of tables that contain certain telegrams that have been introduced into ID = 2 (attacks_with_seconds). In case one wants to match sequence_numbers of telegrams from attacks_with_seconds with those from attack_free_referencedataset_with_seconds, the following applies:
-- For attacks of type 4: Table replay_telegrams shows the same telegrams that have been introduced into attacks_with_seconds but with the original sequence_number as in attack_free_referencedataset_with_seconds. -- For attacks of type 5: Table negation_telegrams shows the same telegrams that have been introduced into attacks_with_seconds but with the original sequence_number as in attack_free_referencedataset_with_seconds. |
Other Systems
Do you have any traffic for CAN, Profibus, Foundation Fieldbus, LON, EIA-485, RS-485 or any other fieldbus technology to offer, please contact Simeon Wiedenmann
Licence
All test cases of this benchmark collection are licensed under the Free Culture License CC BY-SA 4.0 (see [1] for more infos). When using individual test cases the test case author as well as this benchmark collection need to be named: e.g. Test Case by <author> published via [2]